GENERATÖRLERİN PARALEL BAĞLANMASINDA FAZ SIRASININ MİKRODENETLEYİCİ TABANLI TESPİTİ VE OTOMATİK OLARAK DÜZELTİLMESİ

Ilhan GARIP 1

Bu çalışmada generatörlerin paralel bağlanması esnasında, faz sıralarının doğruluğunun ölçülmesi ve otomatik olarak düzeltilmesi mikrodenetleyici tabanlı olarak gerçekleştirilmiştir. Kare dalgaya dönüştürülen bu sinyaller, PIC16F877 mikrodenetleyicisi içerisinde C programlama dilinde yazılmış olan program tarafından değerlendirilmiştir. Sinyaller arasındaki açı farkı 1200 ise A rölesi, açı farkı 00 ise B rölesi devreye alınarak faz sıraları düzeltilmektedir. A ve B rölelerinin kontrol ettikleri A veya B kontaktörü üzerinden sistemin faz sıralarının doğruluğu sağlanmaktadır. Burada fazların A kontaktöründeki bağlantısı B kontaktöründe fazların ikisinin yeri değiştirilerek bağlanmıştır. Mikrodenetleyici yaptığı ölçüme göre devreye A veya B rölesini almaktadır. Deneysel sonuçlar gerçekleştirilen sistemin doğruluğunu ve uygulanabilirliğini göstermiştir.

Keywords
Faz sırası doğrulğu, Paralel bağlama, Faz açısı eşitliği, Mikrodenetleyici, Sıfır geçiş anahtar devresi,

PROVIDING RIGHT PHASE ORDER BASED ON MICROCONTROLLER AND AUTOCORRECTION OF WRONG PHASE ORDER

Ilhan GARIP 1

In this study, the measurements of the accuracy of phase sequence and automatic correction of it have been performed using a microcontroller during the parallel connection of the generators. The voltage signals(R-R, S-S) of two mutual phases of the generator and the network have been converted to a proper level by a designed measurement circuit and then converted to square waves with applying these to the zero crossing circuit. The signals have been evaluated by a program written in C programming language which is inserted into the PIC16F877 Microcontroller. The phase lines are corrected by switching on relay A when the angle difference between the signals is 1200 electrical, or by switching on relay B when the angle difference between the signals is 00 electrical. Using A or B contactors which are controlled by A and B relays, the accuracy of phase lines of the system is provided. Here, the places of the phase connections of A contactor are changed on B contactor. The microcontroller

Keywords
Equality of phase orders, parallel connection, equality of phase angle, Microcontroller, zero pass switching circuit,