AG, SWH AND SE MEMBRANLARLA, TERS OZMOZ KULLANILARAK, KROM KAPLAMA UYGULAMALARINDAN ELDE EDİLEN ATIK SUDAN KROM UZAKLAŞTIRMASI

Aysel Çimen 1

Sudan krom eldesi SWHR, AG, ve SE membranlarla ters ozmoz tekniği kullanılarak araştırıldı.Krom reddetmesi üzerine pH nın, besleme suyunun konsantrasyonunun etkisi ve işlem basıncı araştırıld. Krom reddetmesi membran tipine, besleme suyunun pH sına ve işlem basıncına bağlıdır. Besleme suyunun pH sı etkili krom eldesi için 3 bulundu. En düşük krom konsantrasyonu geçişi AG membranda bulundu. Membranların reddetmesi sırayla AG > SWHR > SE şeklinde bulundu. Bütün membranlar için krom reddetmesi işlem basıncıyla arttı. Ters ozmoz tekniği sıvı atık numuneden krom eldesi %91 oranında başarıldı.

Keywords
Krom eldesi, Ters ozmoz, Membran, pH, AG ,

REMOVAL OF CHROMIUM FROM WASTES OBTAINED FROM CHROMIUM-COATING APPLICATION BY USING REVERSE OSMOSIS WITH AG, SWHR AND SE MEMBRANE

Aysel Çimen 1

The removal of chromium from waste water obtained from chromium-coating application was investigated by using reverse osmosis (RO) technique using FILMTEC SWHR (sea water high rejection) and GE OSMONICS AG and SE (high rejection brackish water) membranes.The effect of pH, concentration of the feed water and operating pressure on the chromium rejection was also investigated. Chromium rejection was dependant on membrane type, pH of the feed water and operating pressure. pH of feed water was found 3 to be optimum effective removal of chromium.The rejection efficiency of the membranes was found to be in the order of AG > SWHR > SE. For all membranes, chromium rejection increased with operating pressure. RO could be efficiently used (with >91% rejection) for the removal of chromium from liquid waste sample.

Keywords
Chromium removal, Reverse osmosis, Membrane, pH, AG ,